Basic Info.
Type
Function Signal Generator
Product Description
PrefaceThank you for purchasing our portable signal generator. This manual describes the function, wiring and operation instructions of the signal generator. To ensure the correct use of the signal generator, please read this manual before use.
1.It is strictly forbidden to copy or publish the contents of this manual.
2.The performance and function of this signal generator will be continuously improved. This manual is subject to change without notice.
3. The company strives to make the manual correct and comprehensive. If there is any mistake or omission, please contact us.
Confirm package content1. Signal generator host 1 set
2. Three signal cables.
3. One USB cable.
4. Charging plug.
5. 1 portable case.
6. One user manual.
7. Certificate of conformity.
I. Overview1.1 IntroductionThe signal generator has a variety of signal measurement and output functions, including voltage, current, thermocouple, thermal resistance, resistance, high-definition LCD screen and silica gel button with distinct functions, simple operation, long standby time, high precision, and programmable output function. It is widely used in the debugging of PLC, process instrument and electric valve in laboratory and industrial field.
1.2 Main functionsVoltage signal: 0 - 30 V, 0 - 25 MV, 0 - 100 mV output and measurement.
Current signal: active and passive 0 - 25mA, 4 - 20mA output and measurement.
Thermocouple: K, E, J, T, R, B, S, N output and measurement.
Thermal resistance: Pt 100 output and measurement.
Resistance: output and measurement of resistance signal
1.3 Technical indicatorsProject | Signal type | Range | Accuracy | Resolution | Remarks |
DC voltage | 20mV | 0. 00- 24. 00mV | ±0. 1% | 0. 01mV | |
100mV | 0. 0- 100. 0mV | ±0. 1% | 0. 1mV | |
V | Output0. 00- 15. 00V | ±0. 1% | 0. 01V | Output: maximum current 30mA Measurement: input impedance 1.2m Ω |
Measure0. 00- 30. 00V | ±0. 1% | 0. 01V |
DC current | mA | 0. 00- 24. 00mA | ±0. 1% | 0. 01mA | Output: maximum load 750 Ω Measurement: input impedance 100 Ω |
4- 20mA | 4/ 8/ 12/ 16/ 20mA | ±0. 1% | 0. 01mA |
Passive current | mA | 0. 00- 24. 00mA | ±0. 1% | 0. 01mA | Output: external power supply 16-30v |
Distribution output | 24VLOOP | 24V/ 16V | 0.1 | 0. 1V | Driving current 24 m A |
Thermocouple | K | - 270- 1372ºC | ±1% | 1ºC | Output: range from 0 ºC. No negative temperature |
E | - 270- 1000ºC | ±1% | 1ºC |
J | - 210- 1200ºC | ±1% | 1ºC |
T | - 270- 400ºC | ±1% | 1ºC |
R | - 50- 1768ºC | ±1% | 1ºC |
B | 0- 1820ºC | ±1% | 1ºC |
S | - 50- 1768ºC | ±1% | 1ºC |
N | - 270- 1300ºC | ±1% | 1ºC |
Thermal resistance | Pt100 | - 200- 850ºC | ±1% | 0.1ºC | Accuracy does not include lead resistance |
Resistance | Ω | 20- 400Ω | ±1% | 0.1Ω |
1.4 Specifications1.4.1 Working temperature and humidity: - 10-55 ºC, 20-80% RH (no condensation)
1.4.2 Storage temperature: - 20 ~ 70 ºC
1.4.3 Overall dimension (mm): 115 * 70 * 26
1.4.4 Weight: 300g
1.4.5 Power supply: 3.7V lithium battery power supply or external 5V / 1A adapter power supply
1.4.6 Power consumption and battery consumption: 300mA, 7-10 hours for full load battery
1.4.7 Reverse connection and overcurrent protection: 30V
2.3 LCD displaya measurement value display: 4-digit 8-word, with unit.
b output signal value: 4-bit 8-word, with unit.
c signal and cold end mode: 20mV / 100mV / 4-20mA / PT100 / Ω / K / E / J / T / R / B / S / N. RJA is the automatic cold end and M is the manual cold end.
d programming function: n / m is divided output, output value = (main setting value) * (n / m)
The sweep is a linear output, which outputs the signal according to the time set by the user.
Step is the step output, and the step output signal is set by the user.
Time is the output time of each step, 0-999S can be grouped.
Count is the number of output cycles, 0-999 times can be grouped, and 0 is infinite cycle.
e unit: MA / MV / V / ºC.
f range conversion function: RL is the display range lower limit, RH is the display range upper limit, SL is the signal lower limit, SH is the signal upper limit.
g battery capacity and charging mark: when charging, the mark flashes. When fully charged, the sign is always on.